Nitrile Gloves HS Code 4015: Import Documents Explained for Importers
A container of nitrile gloves can clear in two days or sit for three weeks with exactly the same cartons inside. The difference is usually a six-digit number and a folder of documents that agree with each other.
Sharmil Mangukiya (Founder & MD) 7 min read November 19, 2026
In short
Most delays on a glove container are not about the gloves. They are about a tariff line that does not match the invoice, or a certificate that names a different product. This guide explains where nitrile examination gloves sit in HS heading 4015, why the 2022 change still causes mistakes, and the documents an importer should have before the ship sails.
Our full specification, packing and MOQ are on the disposable nitrile examination gloves product page. This guide is for importers and distributors bringing nitrile examination gloves into markets such as Nigeria, Kenya, the UAE and Saudi Arabia: which HS code they fall under, what changed in 2022, and the documents that should travel with each shipment so customs and the health regulator see one consistent story.
What is the HS code for disposable nitrile gloves?
Disposable nitrile examination gloves for medical use generally fall under HS 4015.12 — gloves of vulcanised rubber "of a kind used for medical, surgical, dental or veterinary purposes", other than surgical gloves — in the 2022 edition of the Harmonized System. Before 2022 the same gloves were usually declared under 4015.19. Your country adds its own digits after the first six, so always confirm the full national tariff line, and any duty, with your customs agent before you open the import permit or Form M.
How heading 4015 is split
Heading 4015 covers articles of apparel and clothing accessories, including gloves, made of vulcanised rubber other than hard rubber. Nitrile (NBR) counts as synthetic rubber, so nitrile gloves sit here alongside latex gloves. The split that matters to a glove importer is between surgical gloves, other medical gloves, and gloves for every other use.
Subheading (HS 2022)
What it covers
Typical glove
Common mistake
4015.11
Surgical gloves
Sterile latex or synthetic surgical gloves, sized 6.0–9.0
Declaring sterile surgical gloves as examination gloves
4015.12
Other medical, dental or veterinary gloves (not surgical)
Nitrile or latex examination gloves, powder-free, sizes XS–XL
Using the pre-2022 line 4015.19 from an old invoice or catalogue
4015.19
Other gloves, mittens and mitts
Industrial, food-handling or household gloves
Declaring medical gloves here to avoid a health-regulator check
4015.90
Other rubber apparel and accessories
Aprons, sleeves and similar items
Putting glove orders with aprons on one invoice line
The words "of a kind used for" matter. Customs looks at how the glove is made, labelled and sold, not only at who buys it. A box that says "medical examination glove", carries a medical-device standard such as EN 455 or ASTM D6319 and is sold to hospitals belongs in 4015.12, even if a distributor later sells some boxes to a laboratory or a restaurant.
Why a wrong line costs more than the duty difference
In many markets the duty on 4015.12 and 4015.19 is similar, so importers assume the line does not matter. It does, for three reasons:
The regulator flag. Medical gloves are usually regulated as medical devices. Declaring them under a non-medical line can skip the health-regulator check at the border, and when an inspector finds the mismatch the whole consignment is held while it is reclassified.
Documents must agree. The pro forma invoice, the import permit or Form M, the commercial invoice, the certificate of origin and the bill of lading description should all carry the same line and the same product words. One old code on one document is enough to stop clearance.
Exemptions and tenders. Some public tenders and duty concessions for medical supplies are linked to the medical tariff line. A wrong line can mean paying duty you would not otherwise pay, or failing a tender's document check.
Procurement note
Ask your supplier to put the same six-digit code on the pro forma invoice that your customs agent confirmed, before you apply for any import permit. Changing the code after the permit is issued usually means a fresh application, and the ship will not wait for it.
The documents an importer needs for nitrile gloves
Two sets of papers travel with a glove order: the product file the regulator looks at once (or at each renewal), and the shipment documents customs looks at every time. Keep them in separate folders, and check that the product names, sizes and manufacturer address are written the same way in both.
Document
Who issues it
When you need it
What to check
ISO 13485 certificate
Manufacturer's certification body
Registration or import approval
Site address and glove scope match the factory that made your lot
EN 455 / ASTM D6319 test reports
Accredited test lab
Registration; often asked again by hospitals
Report covers nitrile examination gloves, not only latex; dated recently
CE certificate or declaration of conformity
Manufacturer / notified body
Where the buyer or regulator accepts CE as evidence
Product name and model match your boxes
Free sale certificate
Authority in the exporting country
If the import application asks for it
Attestation or legalisation your regulator requires
Pro forma invoice
Supplier
Opening Form M, LC or import permit
HS line, quantity, sizes and Incoterm exactly as on the final invoice
Commercial invoice and packing list
Supplier
Every shipment
Carton numbers, sizes per carton and gross/net weight agree
Bill of lading or airway bill
Shipping line / airline
Every shipment
Description and consignee match the import permit
Certificate of origin
Chamber or export council in India
When the buyer or a trade agreement needs it
Same HS line and description as the invoice
Batch test certificate (COA)
Manufacturer's QC
Every lot
Lot number on the certificate is the lot printed on the boxes
The key checks from this guide at a glance.
Buyer tip
Before the first order, send your supplier a photo of a box you already sell and ask them to mark every field your regulator checks on it: product name, size, lot, manufacturing and expiry dates, standard, manufacturer and importer details. Then ask for their artwork against the same list. Most label problems are found in this ten-minute exercise, not at the port.
Country notes for Nigeria, Kenya, the UAE and Saudi Arabia
The HS code is international, but the import route around it is national. The notes below are where importers in our main markets usually start; requirements change, so verify current guidance with the regulator and your clearing agent before you order.
Market
Health regulator
What the importer usually arranges
What we provide
Nigeria
NAFDAC
Product registration or import permit; Form M through the bank before shipment
Technical file, pro forma with the agreed HS line, labels to NAFDAC artwork
Kenya
Pharmacy and Poisons Board (PPB)
Device registration or listing through a local agent; import permit per consignment
ISO 13485 and test reports, authorisation letter for the local agent
UAE
Ministry of Health and Prevention (MOHAP) / Emirates Drug Establishment
Product registration and an importer licence for medical devices
Certificates, declaration of conformity, Arabic/English label text if needed
Saudi Arabia
Saudi Food and Drug Authority (SFDA)
Medical device marketing authorisation via an authorised representative
Technical documentation and labels in the SFDA format your representative sends
Customs does not read your gloves. It reads your paperwork, and it only needs one page that disagrees with the rest.
Powder-free nitrile examination gloves, sizes XS to XL, 100 per box, to EN 455 and ASTM D6319.
How to import nitrile gloves from India: the order of steps
Confirm the full national tariff line and duty with your customs agent, using the product description and standard printed on the box.
Check whether the product needs registration or an import permit with your health regulator, and who holds it — you, a local agent or the manufacturer's representative.
Collect the product file from the supplier: ISO 13485, test reports, declaration of conformity and label artwork. Check names and addresses match.
Agree the order on a pro forma invoice carrying the confirmed HS line, sizes per carton, packing and Incoterm, and use it for Form M, LC or permit applications.
Before shipment, ask for the draft commercial invoice, packing list and certificate of origin and compare them with the permit, line by line.
On arrival, keep the batch certificate with the clearance file; hospitals and inspectors often ask for it months later.
Our minimum order for disposable nitrile examination gloves is 100,000 pieces, packed 100 gloves per dispenser box and 10 boxes per master carton, and the current lead time is 12 to 18 days from order confirmation before transit. For a price, request a current quotation and compare offers on the same basis: the same thickness and AQL, the same size split, the same packing and the same Incoterm and port. A lower price on a thinner glove or a different AQL is not a saving once a hospital rejects the lot.
Send us your destination port, size split and the HS line your agent confirmed, and we will prepare a pro forma invoice to match.
100% synthetic nitrile medical examination gloves — latex-free, powder-free, micro-textured fingertips with superior chemical and puncture resistance for hospitals, clinics, and laboratories. Container consignments dispatched from Port Mundra & Port Nhava Sheva, with certificates and test reports shared with every quotation.
Made to CE MDRMade to ISO 13485Made to EN 455Made to ASTM D6319MOQ: 100,000 pcs
What is the HS code for disposable nitrile gloves?
Medical nitrile examination gloves generally fall under HS 4015.12 in the 2022 Harmonized System. Older documents often show 4015.19, which now covers non-medical gloves. Confirm the full national line with your customs agent.
Are nitrile gloves classified under 4015.19 or 4015.12?
Since HS 2022, gloves of a kind used for medical, surgical, dental or veterinary purposes (other than surgical gloves) go under 4015.12. Gloves for industrial, food or household use stay under 4015.19. How the glove is made, labelled and sold decides the line.
What is the HS code for surgical gloves?
Surgical gloves have their own subheading, 4015.11. Sterile surgical gloves should not be declared as examination gloves, even when both are in the same container.
What documents are needed to import nitrile gloves?
Usually a commercial invoice, packing list, bill of lading, certificate of origin when required and a batch test certificate for each shipment, plus the product file the health regulator asks for: ISO 13485, test reports to EN 455 or ASTM D6319 and label artwork. Check your country's list with the regulator.
What is the minimum order for nitrile gloves from Manshav Impex?
The minimum order is 100,000 pieces, packed 100 per dispenser box and 10 boxes per master carton. Sizes can usually be split within the order.
Sharmil Mangukiya (Founder & MD)
Sharmil Mangukiya is the founder and managing director of Manshav Impex, an Indian manufacturer & exporter of medical disposables serving importers, distributors, hospitals and governments in 48+ countries since 2019.